53 research outputs found

    Diagnosis of pancreaticobiliary malignancy by detection of minichromosome maintenance protein 5 in bile aspirates

    Get PDF
    Biliary brush cytology is the standard method of sampling a biliary stricture but has a low sensitivity for the detection of malignancy. We have previously shown that minichromosome maintenance (MCM) replication proteins (Mcm2–7) are markers of dysplasia and have utilised these novel biomarkers of growth for the diagnosis of cervical and bladder cancer. We aimed to determine if MCM proteins are dysregulated in malignant pancreaticobiliary disease and if levels in bile are a sensitive marker of malignancy. In 30 tissue specimens from patients with malignant/benign biliary strictures, we studied Mcm2 and -5 expression by immunohistochemistry. Bile samples were also collected prospectively at endoscopic retrograde cholangiopancreatography from 102 consecutive patients with biliary strictures of established (n=42) or indeterminate aetiology (n=60). Patients with indeterminate strictures also underwent brush cytology as part of standard practice. Bile sediment Mcm5 levels were analysed using an automated immunofluorometric assay. In benign biliary strictures, Mcm2 and -5 protein expression was confined to the basal epithelial proliferative compartment – in contrast to malignant strictures where expression was seen in all tissue layers. The percentage of nuclei positive for Mcm2 was higher in malignant tissue (median 76.5%, range 42–92%) than in benign tissue (median 5%, range 0–33%) (P<0.0005), with similar results for Mcm5. Minichromosome maintenance protein 5 levels in bile were significantly more sensitive than brush cytology (66 vs 20%; P=0.004) for the detection of malignancy in patients with an indeterminate stricture, with a comparable positive predictive value (97 vs 100%; P=ns). In this study, we demonstrate that Mcm5 in bile detected by a simple automated test is a more sensitive indicator of pancreaticobiliary malignancy than routine brush cytology

    The diagnostic accuracy of US, CT, MRI and 1H-MRS for the evaluation of hepatic steatosis compared with liver biopsy: a meta-analysis

    Get PDF
    OBJECTIVE: To meta-analyse the diagnostic accuracy of US, CT, MRI and (1)H-MRS for the evaluation of hepatic steatosis. METHODS: From a comprehensive literature search in MEDLINE, EMBASE, CINAHL and Cochrane (up to November 2009), articles were selected that investigated the diagnostic performance imaging techniques for evaluating hepatic steatosis with histopathology as the reference standard. Cut-off values for the presence of steatosis on liver biopsy were subdivided into four groups: (1) >0, >2 and >5% steatosis; (2) >10, >15 and >20%; (3) >25, >30 and >33%; (4) >50, >60 and >66%. Per group, summary estimates for sensitivity and specificity were calculated. The natural-logarithm of the diagnostic odds ratio (lnDOR) was used as a single indicator of test performance. RESULTS: 46 articles were included. Mean sensitivity estimates for subgroups were 73.3-90.5% (US), 46.1-72.0% (CT), 82.0-97.4% (MRI) and 72.7-88.5% ((1)H-MRS). Mean specificity ranges were 69.6-85.2% (US), 88.1-94.6% (CT), 76.1-95.3% (MRI) and 92.0-95.7% ((1)H-MRS). Overall performance (lnDOR) of MRI and (1)H-MRS was better than that for US and CT for all subgroups, with significant differences in groups 1 and 2. CONCLUSION: MRI and (1)H-MRS can be considered techniques of choice for accurate evaluation of hepatic steatosi

    MR fluoroscopy in vascular and cardiac interventions (review)

    Get PDF
    Vascular and cardiac disease remains a leading cause of morbidity and mortality in developed and emerging countries. Vascular and cardiac interventions require extensive fluoroscopic guidance to navigate endovascular catheters. X-ray fluoroscopy is considered the current modality for real time imaging. It provides excellent spatial and temporal resolution, but is limited by exposure of patients and staff to ionizing radiation, poor soft tissue characterization and lack of quantitative physiologic information. MR fluoroscopy has been introduced with substantial progress during the last decade. Clinical and experimental studies performed under MR fluoroscopy have indicated the suitability of this modality for: delivery of ASD closure, aortic valves, and endovascular stents (aortic, carotid, iliac, renal arteries, inferior vena cava). It aids in performing ablation, creation of hepatic shunts and local delivery of therapies. Development of more MR compatible equipment and devices will widen the applications of MR-guided procedures. At post-intervention, MR imaging aids in assessing the efficacy of therapies, success of interventions. It also provides information on vascular flow and cardiac morphology, function, perfusion and viability. MR fluoroscopy has the potential to form the basis for minimally invasive image–guided surgeries that offer improved patient management and cost effectiveness

    Search for excited leptons in proton-proton collisions at s = 8 s=8 \sqrt{s}=8 TeV

    Full text link

    AVM's of Lateral and Sigmoid Sinuses

    No full text

    The “geographic” liver

    No full text
    corecore